{"id":4812,"date":"2025-04-08T16:39:53","date_gmt":"2025-04-08T09:39:53","guid":{"rendered":"https:\/\/tesfa.vn\/en\/?p=4812"},"modified":"2025-04-08T16:39:53","modified_gmt":"2025-04-08T09:39:53","slug":"power-quality-understanding-harmonics","status":"publish","type":"post","link":"https:\/\/tesfa.vn\/en\/power-quality-understanding-harmonics\/","title":{"rendered":"Power Quality: Understanding Harmonics"},"content":{"rendered":"<p class=\"whitespace-pre-wrap break-words\" style=\"text-align: justify;\">Power quality is a top priority in industries to ensure the proper operation of production systems and monitoring systems in factories. Today, <span style=\"color: #d83131;\"><a style=\"color: #d83131;\" href=\"https:\/\/tesfa.vn\/en\/power-quality-understanding-harmonics\/\"><strong>harmonic distortion<\/strong><\/a><\/span> is a common phenomenon in electrical systems and represents an important factor in ensuring power quality. Let&#8217;s explore harmonics and their harmful effects with Tesfa through this article.<\/p>\n<h2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\" style=\"text-align: justify;\">What are Harmonics?<\/h2>\n<p class=\"whitespace-pre-wrap break-words\" style=\"text-align: justify;\">Harmonics are unwanted distortion waves that directly harm and affect electrical power systems. In electrical systems designed to operate stably at specific frequencies (typically 50Hz), high-order wave components are generated during power transmission and blend into the electrical system due to non-linear loads. These combine with the fundamental frequency, distorting the waveform of the distribution system.<\/p>\n<figure id=\"attachment_5554\" aria-describedby=\"caption-attachment-5554\" style=\"width: 800px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-5554 size-full\" title=\"Th\u00e0nh ph\u1ea7n c\u01a1 b\u1ea3n c\u1ee7a s\u00f3ng h\u00e0i \" src=\"https:\/\/tesfa.vn\/wp-content\/uploads\/2024\/09\/Thanh-phan-co-ban-cua-song-hai.webp\" alt=\"s\u00f3ng h\u00e0i\" width=\"800\" height=\"500\" \/><figcaption id=\"caption-attachment-5554\" class=\"wp-caption-text\">Basic components of harmonics<\/figcaption><\/figure>\n<h2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\" style=\"text-align: justify;\">How are Harmonics Calculated?<\/h2>\n<p class=\"whitespace-pre-wrap break-words\" style=\"text-align: justify;\">Harmonics are characterized as multiples of the fundamental frequency. For example, in a 50Hz electrical system, the 5th harmonic will have a frequency of 250Hz, the 7th harmonic will have a frequency of 350Hz, and so on.<\/p>\n<p class=\"whitespace-pre-wrap break-words\" style=\"text-align: justify;\">The total voltage harmonic distortion is the ratio between the RMS value of the voltage harmonics and the RMS value of the fundamental voltage, calculated according to the following formula:<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-5548 size-full\" title=\"T\u1ed5ng bi\u1ebfn d\u1ea1ng s\u00f3ng h\u00e0i d\u00f2ng \u0111i\u1ec7n\" src=\"https:\/\/tesfa.vn\/wp-content\/uploads\/2024\/09\/Cong-thuc-tinh-song-hai-1.webp\" alt=\"T\u1ed5ng bi\u1ebfn d\u1ea1ng s\u00f3ng h\u00e0i d\u00f2ng \u0111i\u1ec7n\" width=\"262\" height=\"118\" \/><\/p>\n<p class=\"whitespace-pre-wrap break-words\" style=\"text-align: justify;\">The total current harmonic distortion is the ratio between the RMS value of the current harmonics and the RMS value of the fundamental current at maximum load or power generation mode, calculated according to the following formula:<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-5547 size-full\" title=\"T\u1ed5ng bi\u1ebfn d\u1ea1ng s\u00f3ng h\u00e0i \u0111i\u1ec7n \u00e1p \" src=\"https:\/\/tesfa.vn\/wp-content\/uploads\/2024\/09\/Cong-thuc-tinh-song-hai-2.webp\" alt=\"T\u1ed5ng bi\u1ebfn d\u1ea1ng s\u00f3ng h\u00e0i \u0111i\u1ec7n \u00e1p\" width=\"287\" height=\"117\" \/><\/p>\n<h2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\" style=\"text-align: justify;\">Causes of Harmonics<\/h2>\n<p class=\"whitespace-pre-wrap break-words\" style=\"text-align: justify;\">The main causes of harmonics are non-linear loads in the electrical system such as high-frequency furnaces, inverters, power electronic devices, lighting systems using LED or fluorescent technology, computers, UPS systems, etc. These non-linear loads are an essential part of manufacturing plants and are the primary factors causing sine wave distortion.<\/p>\n<div class=\"row\"  id=\"row-283445383\">\n\n\t<div id=\"col-701327445\" class=\"col medium-1\/3 large-4\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<figure id=\"attachment_5556\" aria-describedby=\"caption-attachment-5556\" style=\"width: 800px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-5556 size-full\" title=\"Bi\u1ebfn t\u1ea7n \" src=\"https:\/\/tesfa.vn\/wp-content\/uploads\/2024\/09\/Bien-tan-1.webp\" alt=\"Bi\u1ebfn t\u1ea7n \" width=\"800\" height=\"500\" \/><figcaption id=\"caption-attachment-5556\" class=\"wp-caption-text\">Inverter<\/figcaption><\/figure>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-459544607\" class=\"col medium-1\/3 large-4\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<figure id=\"attachment_5553\" aria-describedby=\"caption-attachment-5553\" style=\"width: 800px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-5553 size-full\" title=\"L\u00f2 nung cao t\u1ea7ng trong nh\u00e0 m\u00e1y s\u1ea3n xu\u1ea5t \" src=\"https:\/\/tesfa.vn\/wp-content\/uploads\/2024\/09\/Lo-nung-cao-tang-trong-nha-may-san-xuat.webp\" alt=\"L\u00f2 nung cao t\u1ea7ng trong nh\u00e0 m\u00e1y s\u1ea3n xu\u1ea5t \" width=\"800\" height=\"500\" \/><figcaption id=\"caption-attachment-5553\" class=\"wp-caption-text\"><em>High-rise furnace in factory<\/em><\/figcaption><\/figure>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1421163966\" class=\"col medium-1\/3 large-4\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<figure id=\"attachment_5555\" aria-describedby=\"caption-attachment-5555\" style=\"width: 800px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-5555 size-full\" title=\"H\u1ec7 th\u1ed1ng m\u00e1y t\u00ednh nh\u00e0 m\u00e1y \" src=\"https:\/\/tesfa.vn\/wp-content\/uploads\/2024\/09\/He-thong-may-tinh-nha-may-1.webp\" alt=\"H\u1ec7 th\u1ed1ng m\u00e1y t\u00ednh nh\u00e0 m\u00e1y \" width=\"800\" height=\"500\" \/><figcaption id=\"caption-attachment-5555\" class=\"wp-caption-text\"><em>Factory computer system<\/em><\/figcaption><\/figure>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<h2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\" style=\"text-align: justify;\">Regulatory Standards<\/h2>\n<p class=\"whitespace-pre-wrap break-words\" style=\"text-align: justify;\">Since harmonics are an important factor that reduces the power quality of the system and causes damage to other equipment in manufacturing plants, Vietnam and countries worldwide have established many standards to evaluate the severity of harmonics. One of these standards is IEEE 519 from the Institute of Electrical and Electronics Engineers, USA, and the standard according to Circular No. TT30\/2019\/TT-BCT of the Ministry of Industry and Trade of Vietnam.<\/p>\n<table>\n<tbody>\n<tr>\n<td><strong><span style=\"color: #000000;\">Standards<\/span><\/strong><\/td>\n<td>\n<p style=\"text-align: center;\"><strong>Voltage harmonic distortion<\/strong><\/p>\n<\/td>\n<td>\n<p style=\"text-align: center;\"><strong>Current harmonic distortion<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p style=\"text-align: left;\"><span style=\"font-weight: 400; color: #000000;\">TT30 BCT VN<\/span><\/p>\n<\/td>\n<td style=\"text-align: center;\"><span style=\"font-weight: 400; color: #000000;\">8%<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-weight: 400; color: #000000;\">12%<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">\n<p style=\"text-align: left;\"><span style=\"font-weight: 400; color: #000000;\">IEEE 519<\/span><\/p>\n<\/td>\n<td style=\"text-align: center;\"><span style=\"font-weight: 400; color: #000000;\">8%<\/span><\/td>\n<td>\n<p style=\"text-align: center;\"><span style=\"font-weight: 400; color: #000000;\">5%<\/span><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\" style=\"text-align: justify;\">Harmful Effects of Harmonics<\/h2>\n<p class=\"whitespace-pre-wrap break-words\" style=\"text-align: justify;\">Harmonics are unwanted disturbances that directly affect power quality. They appear when using non-linear loads and severely affect equipment and machinery used in factories, including:<\/p>\n<ul class=\"[&amp;:not(:last-child)_ul]:pb-1 [&amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\">\n<li class=\"whitespace-normal break-words\" style=\"text-align: justify;\">Reduced motor lifespan<\/li>\n<li class=\"whitespace-normal break-words\" style=\"text-align: justify;\">Overloading circuit breakers, overheating, and causing transformer fires and explosions<\/li>\n<li class=\"whitespace-normal break-words\" style=\"text-align: justify;\">Circuit breakers, automatic switches, and fuses may trip without apparent cause<\/li>\n<li class=\"whitespace-normal break-words\" style=\"text-align: justify;\">Reduced lifespan of compensation capacitors, even causing abnormal capacitor explosions<\/li>\n<li class=\"whitespace-normal break-words\" style=\"text-align: justify;\">Causing interference affecting telecommunications equipment and automation systems<\/li>\n<li class=\"whitespace-normal break-words\" style=\"text-align: justify;\">Inaccurate operation of measuring devices<\/li>\n<li class=\"whitespace-normal break-words\" style=\"text-align: justify;\">Energy waste<\/li>\n<li class=\"whitespace-normal break-words\" style=\"text-align: justify;\">Equipment overheating and fire hazards<\/li>\n<\/ul>\n<figure id=\"attachment_5551\" aria-describedby=\"caption-attachment-5551\" style=\"width: 800px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-5551 size-full\" title=\"Thi\u1ebft b\u1ecb qu\u00e1 nhi\u1ec7t v\u00e0 ch\u00e1y n\u1ed5 \" src=\"https:\/\/tesfa.vn\/wp-content\/uploads\/2024\/09\/Thiet-bi-qua-nhiet-va-chay-no.webp\" alt=\"Thi\u1ebft b\u1ecb qu\u00e1 nhi\u1ec7t v\u00e0 ch\u00e1y n\u1ed5 \" width=\"800\" height=\"500\" \/><figcaption id=\"caption-attachment-5551\" class=\"wp-caption-text\">Overheating and fire equipment<\/figcaption><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Power quality is a top priority in industries to ensure the proper operation of production systems and monitoring systems in factories. Today, harmonic distortion is a common phenomenon in electrical systems and represents an important factor in ensuring power quality. Let&#8217;s explore harmonics and their harmful effects with Tesfa through this article. What are Harmonics?&#8230;<\/p>\n","protected":false},"author":2,"featured_media":4813,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"inline_featured_image":false,"pgc_sgb_lightbox_settings":"","footnotes":""},"categories":[198],"tags":[],"class_list":["post-4812","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-kien-thuc-chung"],"_links":{"self":[{"href":"https:\/\/tesfa.vn\/en\/wp-json\/wp\/v2\/posts\/4812","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tesfa.vn\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/tesfa.vn\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/tesfa.vn\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/tesfa.vn\/en\/wp-json\/wp\/v2\/comments?post=4812"}],"version-history":[{"count":2,"href":"https:\/\/tesfa.vn\/en\/wp-json\/wp\/v2\/posts\/4812\/revisions"}],"predecessor-version":[{"id":4815,"href":"https:\/\/tesfa.vn\/en\/wp-json\/wp\/v2\/posts\/4812\/revisions\/4815"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tesfa.vn\/en\/wp-json\/wp\/v2\/media\/4813"}],"wp:attachment":[{"href":"https:\/\/tesfa.vn\/en\/wp-json\/wp\/v2\/media?parent=4812"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/tesfa.vn\/en\/wp-json\/wp\/v2\/categories?post=4812"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/tesfa.vn\/en\/wp-json\/wp\/v2\/tags?post=4812"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}